Ambient Air Quality Monitoring (AAQMS)

Ambient Air Quality Monitoring (AAQMS)

Our team will tailor your ambient air quality monitoring based on your unique needs.

We have solutions ranging from indicative monitors to regulatory compliant AAQMS.

Ektimo offer a comprehensive range of ambient air quality monitoring services to all industries. We support the design and implementation of suitable monitoring regimes depending on your specific situation and needs.

Monitoring programs are designed taking into consideration state-based regulations (ie Victorian Environment Reference Standard (ERS)) and the National Environment Protection Measures (NEPM) for ambient air quality.

A complete end-to-end solution when it comes to AAQMS; consulting, scoping, commissioning, monitoring, sampling, analysis, servicing, calibrating, data validation and reporting.

NATA accredited according to a range of AS 3580 series methods, and regulatory compliant with Australian requirements.

Siting Requirements PM10 PM2.5

  • AS 3580.1.1 – Guide to siting air monitoring equipment

PM10

  • AS 3580.9.6 – Determination of suspended particulate matter – PM10 high volume sampler with size selective inlet – Gravimetric Method
  • AS 3580.9.7 – Determination of suspended particulate matter – Dichotomous sampler (PM10, coarse PM and PM2.5) – Gravimetric Method
  • AS 3580.9.8 – Determination of suspended particulate matter – PM10 continuous direct mass method using a TEOM
  • AS 3580.9.9 – Determination of suspended particulate matter – PM10 low volume sampler – Gravimetric method
  • AS 3580.9.11 – Determination of suspended particulate matter — PM10 beta attenuation monitors
  • AS 3580.9.16 – Determination of suspended particulate matter – PM10 continuous direct mass method using a TEOM incorporating a FDMS unit

PM2.5

  • AS 3580.9.10 – Determination of suspended particulate matter – PM2.5 low volume sampler – Gravimetric method
  • AS 3580.9.12 – Determination of suspended particulate matter – PM2.5 beta attenuation monitors
  • AS 3580.9.13 – Determination of suspended particulate matter – PM2.5 continuous direct mass method using a TEOM
  • AS 3580.9.14 – Determination of suspended particulate matter – PM2.5 high volume sampler with size selective inlet – Gravimetric Method

Particulate Matter (TSP)

  • AS 3580.9.3 – Determination of suspended particulate matter – Total suspended particulates (TSP) – High volume sampler – Gravimetric method
  • AS 3580.10.1 – Determination of particulate matter – Deposited matter – Gravimetric method

Nitrogen Oxides (NO & NO2)

  • AS 3580.5.1 – Determination of oxides of nitrogen – Direct reading instrumental method

Sulfur Dioxide (SO2)

  • AS 3580.4.1 – Determination of sulfur dioxide – Direct reading instrumental method

Ozone (O3)

  • AS 3580.6.1 – Determination of ozone – Direct reading instrumental method

Carbon Monoxide (CO)

  • AS 3580.7.1 – Determination of carbon monoxide – Direct reading instrumental method

Metals

  • AS 3580.9.15 – Determination of suspended particulate matter – Particulate metals high or low volume sample gravimetric collection – Inductively coupled plasma (ICP) spectrometric method

Methane (CH4) & Non-Methane Organics

  • AS 3580.11.1 – Determination of methane and non-methane organic compounds in ambient air – Direct reading instrumental method

Fluoride (F)

  • AS 3580.13.2 – Determination of gaseous and acid-soluble particulate fluorides – Manual, double filter paper sampling

Polycyclic Aromatic Hydrocarbons (PAH’s)

  • AS 3580.16 – Determination of polycyclic aromatic hydrocarbons (PAH)

Road Tunnels

  • AS 3580.18 – Measurement of road tunnel air quality

Weather / Meteorological

  • AS 3580.14 – Meteorological monitoring for ambient air quality monitoring applications

Data Validation

  • AS 3580.19 – Ambient air quality data validation and reporting

Experts in air quality, odour and emission monitoring.

Ektimo is accredited with the National Association of Testing Authorities (NATA) for air emission monitoring methods in Australia, including the industry standard AS, USEPA and ISO methods. For full details of Ektimo’s scope of accreditation, search for Ektimo on the NATA website.

Contact us to speak to one of our industry experts about how we can help on your next project.

Contact Us

If you have an enquiry, please contact us and our team will be happy to assist you. Email us at mailto:info@ektimo.com.au or fill out the form.

Australia
1300 364 005
International
+61 2 4003 3296