Emission monitoring is our specialty, having served industry for nearly 40 years.
We support your regulatory compliance and emission monitoring needs.
Whatever your industry, Ektimo has experience in it. With the largest monitoring team in Australia, we have accumulated a body of knowledge which translates into efficiently run projects.
Our national presence also ensures responsive and timely service across Australia.
Sampling Plane Assessment
- AS 4323.1-2021 Selection of sampling positions and measurement of velocity in stacks
- USEPA Method 1— Sample and Velocity Traverses
for Stationary Sources - NSW EPA TM-1
- SA EPA 03.09
Velocity, Flow Rate & Temperature
- USEPA Method 2 Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S Pitot Tube)
- ISO10780 Stationary source emissions — Measurement of velocity and volume flowrate of gas streams in ducts
- NSW EPA TM-2
- SA EPA 03.10
Moisture
- USEPA Method 4 Determination of Moisture Content in Stack Gases
- USEPA Method ALT-008 Alternative Moisture
Measurement Method Midget Impingers - SA EPA 03.13
Particulate Matter (PM)
- AS 4323.2-2023 Stationary source emissions – total particulate matter- Isokinetic manual sampling
- USEPA Method 5 Determination of particulate matter emissions from stationary sources
- USEPA Method 5B Determination of nonsulfuric acid particulate matter emissions from stationary sources
- USEPA Method 17 Determination of particulate matter emissions from stationary sources
- NSW EPA TM-15
- SA EPA 03.01
PM10 & PM2.5
- USEPA Method 201A Determination of PM10 and PM2.5 emissions from stationary sources
- NSW EPA OM-5
Sulfur Dioxide (SO2)
- USEPA Method 6 Determination of sulfur dioxide emissions from stationary sources
- USEPA Method 6C Determination of Sulfur Dioxide Emissions from Stationary Sources (Instrumental Analyzer Procedure)
- USEPA Method 8 Determination of sulfuric acid mist and sulfur dioxide emissions from stationary sources
- NSW EPA TM-4
- SA EPA 03.14
Nitrogen Oxides (NO & NO2)
- USEPA Method 7E Determination of Nitrogen Oxides Emissions from Stationary Sources (Instrumental Analyzer Procedure)
- NSW EPA TM-11
- SA EPA 03.14
Sulfuric Acid Mist (H2SO4) / or Sulfur Trioxide (SO3)
- USEPA Method 8 Determination of sulfuric acid mist and sulfur dioxide emissions from stationary sources
- NSW EPA TM-3
- SA EPA 03.02
Carbon Dioxide (CO2)
- Method 3A – Determination of Oxygen and Carbon Dioxide Concentrations in Emissions From Stationary Sources (Instrumental Analyzer Procedure)
- NSW EPA TM-24
- SA EPA 03.08
- SA EPA 03.14
Oxygen (O2)
- Method 3A – Determination of Oxygen and Carbon Dioxide Concentrations in Emissions From Stationary Sources (Instrumental Analyzer Procedure)
- NSW EPA TM-25
- SA EPA 03.08
- SA EPA 03.14
Carbon Monoxide (CO)
- USEPA Method 10 Determination of Carbon Monoxide Concentrations From Stationary Sources (Instrumental Analyzer Procedure)
- NSW EPA TM-32
- SA EPA 03.12
- SA EPA 03.14
Total Reduced Sulfur (TRS)
- USEPA Method 16A Determination of total reduced sulfur emissions from stationary sources (impinger technique)
- USEPA Method 16C Determination of Total Reduced Sulfur Emissions From Stationary Sources (Instrumental Analyzer Procedure)
- NSW EPA TM-33
Hydrogen Sulfide (H2S)
- USEPA Method 11 Determination of hydrogen sulfide (H2S) content of fuel gas streams in petroleum refineries
- NSW EPA TM-5
Volatile Organic Compounds (VOC)
- USEPA Method 18 Measurement of gaseous organic compound emissions by gas chromatography
- NSW EPA TM-34
- NSW EPA TM-20
Total Organic Compounds (TOC)
- USEPA Method 25A Determination of Total Gaseous Organic Concentration Using a Flame Ionisation Analyzer (FID)
- USEPA Method 25B – Determination of Total Gaseous Organic Concentration Using a Nondispersive Infrared Analyzer (NDIR)
- NSW EPA TM-34
Mercury (Hg)
- USEPA Method 29 Determination of metals emissions from stationary sources
- USEPA Method 30B Determination of Total Vapour Phase Mercury Emissions from Coal-Fired Combustion Sources Using Carbon Sorbent Traps
- NSW EPA TM-34
Metals
- USEPA Method 29 Determination of metals emissions from stationary sources
- NSW EPA TM-12, TM-13, TM-14
- SA EPA 03.07
Hydrogen Chloride (HCl)
- USEPA Method 26 – Determination of Hydrogen Chloride Emissions From Stationary Sources
- USEPA Method 26A Determination of hydrogen halide and halogen emissions from stationary sources isokinetic method
- NSW EPA TM-8
Hydrogen Fluoride (HF)
- USEPA Method 13B Determination of Total Fluoride Emissions From Stationary Sources (Specific Ion Electrode Method)
- NSW EPA TM-9
Formaldehyde, Aldehydes & Ketones
- SW-846 Test Method 0011: Sampling for Selected Aldehyde and Ketone Emissions from Stationary Sources
- NSW EPA OM-11
Polycyclic Aromatic Hydrocarbons (PAHs)
- CARB Method 429 Determination of Polycyclic Aromatic Hydrocarbon (PAH) Emissions from Stationary Sources
- SW-846 Test Method 0010: Modified Method 5 Sampling Train Determination of Destruction and Removal Efficiency (DRE) of semivolatile Principal Organic Hazardous Compounds (POHCs) from incineration systems
- NSW EPA OM-6
Hexavalent Chromium (Cr)
- CARB Method 425 Determination of Total Chromium and Hexavalent Chromium Emissions from Stationary Sources
- SW-846 Test Method 0061: Determination of Hexavalent Chromium Emissions from Stationary Sources
- SW EPA OM-4
Phenols
- USEPA CTM-032 Draft Method for Sampling and Analysis for High Levels of Phenol and Cresol Emissions from Stationary Sources
Dioxins or Furans
- USEPA Method 23 Determination of Polychlorinated Dibenzo-p-Dioxins and Polychlorinated Dibenzofurans From Stationary Sources
- NSW EPA TM-18
Experts in air quality, odour and emission monitoring.
Ektimo is accredited with the National Association of Testing Authorities (NATA) for air emission monitoring methods in Australia, including the industry standard AS, USEPA and ISO methods.
For full details of Ektimo’s scope of accreditation, search for Ektimo on the NATA website.
Contact us to speak to one of our industry experts about how we can help on your next project.